Zenith Pumps Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Pompes Zenith Pumps. Zenith Pumps User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 12
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Zenith
®
Pumps
Installation,
Care and
Maintenance
Zenith
Polymer
Extrusion
Gear Pumps
PEP-II Series
Gear Pumps
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Gear Pumps

Zenith®PumpsInstallation,Care andMaintenanceZenithPolymerExtrusionGear PumpsPEP-II SeriesGear Pumps

Page 2 - Benefits

Size (UNC Recommended Alloy Steel) Torque (in-lbs)1/2-13 9229/16-12 1,3315/8-11 1,8363/4-10 3,2577/8-9 5,8001-8 8,0001 1/8-7 12,00010Reassemblycontin

Page 3

11TroubleshootingParts ReplacementWhen ordering replacement parts, please be sure to include the following information:1) Pump model number2) Part num

Page 4 - Dimensional Diagram

FAILURE, IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROP

Page 5 - 5-750 cc/rev

Zenith®Pumps2Thoroughly read and understand this entire manual before installation and operation of pump.BenefitsSpecificationsCapacities: 0.16 to 750

Page 6 - Installation

Zenith®Pumps and The Extrusion ProcessDesignZenith Pumps can handle all your extrusion pumping applications including additive injection for on-line c

Page 7 - Disassembly

PEP-II Pump0.16-3 cc/revITEM QTY PART MATERIAL1 1 FRONT PLATE TOOL STEEL2 1 CENTER PLATE TOOL STEEL3 1 REAR PLATE TOOL STEEL4 1 DRIVE SHAFT TOOL STEE

Page 8 - Schematic

ITEM QTY PART MATERIAL1 1 DRIVING GEAR SHAFT TOOL STEEL2 1 DRIVEN GEAR SHAFT TOOL STEEL3 1 CENTER PLATE TOOL STEEL4 2 COVER PLATE 41406 2 BEARING TOOL

Page 9

Operation6InstallationPolymer enters the PEP-II pump on thesuction side where shaft rotation exposesgear tooth volumes between the gearteeth. Polymer

Page 10 - ISO View

Cleaning,Inspection,Repair andService7DisassemblyAfter removal from the system, the assem-bled pump can be cleaned by placing itin a suitable furnace

Page 11 - Replacement

Disassemblycontinued8D-Bearing OrientationSchematicplate and set aside in a safe place to pre-vent damage. At this point, make certainto note the orie

Page 12 - ISO 9001: 2000 Registered

Reassembly9These instructions should be thoroughlyread and understood before startingreassembly.General instructions that should beobserved to ensure