Vue de la page 6
7
BPB Series
Disassembly
Refer to Diagram 1 on Page 10 (general
reference only).
Note: As parts are disassembled, place
them carefully on a clean surface such
as a soft cloth. Do not allow them to
knock together.
1) Remove Outer Drive Gear (18) by first
removing Drive Strap Screws (28) and
Drive Strap (20). Slide Yoke Retainer
(19) out of slot in Hub (12).
2) Pull Outer Drive Shaft (11) out of
Hub (12).
3a) LIP SEAL DESIGN. Place pump in a
soft-jawed vise with the Hub (12)
facing upward. Never clamp on
lapped surfaces. Remove three #10-
24 Hub Screws (27) and Hub (12).
Note: We strongly advise removing
the Lip Seal (14) from the Hub (12)
and discarding it.
3b) METAL SEAL DESIGN. Place pump
in a soft-jawed vise with the Hub (12)
facing upward. Never clamp on
lapped surfaces. Upon removal of
the three #10-24 Hub Screws (27),
the Hub (12), Coupling Housing (13),
Anchor Washer (15) and Universal
Seal Coupling (14) are all easily
removed. Remove and carefully
store the Compression Spring (16).
4) Turn the pump over and clamp the
vise onto the Front Side Plate (1).
Remove two of the diagonally opposed
#12-24 Binder Screws (21). Loosen
the other two screws but leave them
engaged by two or three threads.
5) Separate the Front Side Plate (1) and
Rear Side Plate (3) by gently tapping
the slightly engaged Binder Screws
(21) with a plastic hammer.
6) Lift off the Rear Side Plate (3), Center
Plate (2) and Spacer (9).
Caution: Do not allow the metering gears
to be lifted out with the Center Plate (2).
They may drop, causing damage to the
gear teeth. On Metal Seal Design
pumps, be careful to retain Ball (29).
7) Remove Driving Metering Gear As-
sembly (6) by gently turning and lifting.
Repeat for Driven Metering Gear (7).
Never use pliers to lift gears. Never
use a screwdriver to pry gear upward.
If there is a film of oil or other tena-
cious fluid between the gear and the
side plate, it helps to immerse the
parts in solvent. On Metal Seal Design
pumps, Driving Metering Gear (6) and
Drive Shaft (4) are not a press fit
assembly.
8) Remove Port Seal Screws (23 & 25)
and Gaskets (22 & 24). Repeat for
Shaft Seal Screw (31) and Gasket (30).
9) If the Arbor (5) is to be replaced or
thoroughly checked, press out by
using an arbor tool, pressing towards
the inside of the pump (the shortest
press direction). Repeat for Dowels (10).